Appliances you supply in a let property must be tested at least every five years in Scotland. We test one flat or a whole portfolio, collect keys from the agent and send each property its own report.
Portable appliance testing · Dundee & Tayside
Your appliances inspected, tested and labelled. You get a certificate and a full results PDF, and a reminder when the next test is due.
What every customer gets
The same five things on every job, whether it is six items in a rented flat or six thousand across several buildings.
Each item gets a proper visual inspection and then the electrical tests that suit it. Nothing is stickered without being checked.
Every item is labelled with the result, its own ID number, the test date and the date the next test is due.
Anything that fails is shown to you on the day, with what is wrong and what it needs, so you are never left guessing from a sticker.
You get a test certificate and a PDF listing every item and its readings, ready for your insurer, letting agent, council or venue.
We keep your register and get in touch when the next test is due, so the date never slips past you.
The basics
PAT stands for portable appliance testing. It is a routine safety check of electrical equipment that plugs in.
Each item is looked over for damage, then tested with a calibrated instrument to make sure it is safe to use. Items that pass get a green label. Items that fail get a red one and are taken out of use until they are fixed.
Portable items include power tools, food mixers, kettles, lamps, TVs, heaters, computers and chargers, among many others.
A simple rule: if it has a plug and can be moved, it falls within the scope of a PAT test. Fixed wiring in the walls is not covered. That is checked by an EICR instead.
Washing machines, dishwashers and vending machines are not exactly portable, but they are movable, so they count.
Need the fixed wiring checked as well? Dundee Sparks carries out EICRs, and both can be booked for the same visit. See the main Dundee electrician site.
Six items or six thousand
If you are an employer, landlord, shop owner or business owner, you have a duty of care to the people who use your premises: your staff, tenants, customers and the public.
Part of that duty is making sure the electrical appliances they use, or are near, are safe. You are the duty holder. Your insurer may also make regular testing a condition of your policy.
Our service suits every size of customer, from one rented flat to businesses with several locations and item counts in the many thousands.
Appliances you supply in a let property must be tested at least every five years in Scotland. We test one flat or a whole portfolio, collect keys from the agent and send each property its own report.
Tills, card machines, grills, fridges, dryers and the extension leads behind the counter. Testing is done before you open or after you close, so customers never see it.
Many venues, weddings and festivals will not let you plug in without a current PAT certificate. Amps, mixers, lights and every lead are tested, and the certificate is emailed so you can forward it.
Computers, monitors, chargers, kitchen appliances and the leads under every desk. We work round your staff a desk at a time, or come in the evening or at the weekend.
Item counts in the thousands are tested over planned visits, building by building. Every item has its own ID, so one register covers all your sites and next year's visit is quicker.
Hall hirers, playgroups and community groups are often asked for test records by their insurer or the hall owner. Small counts are welcome and fall under the £74.99 minimum visit.
The law and your insurer
Scots law is firmer on appliance testing than the rest of the UK for landlords, and every employer has to be able to show their equipment is kept safe.
Under the Repairing Standard in the Housing (Scotland) Act 2006, landlords must have an electrical safety inspection at least every five years. It has two parts: an EICR on the fixed wiring and a PAT test on the appliances the landlord supplies.
Tenants must be given a copy, and a new tenant should get one before they move in.
The Electricity at Work Regulations 1989 require electrical equipment that could cause danger to be maintained in a safe condition. The Health and Safety at Work Act puts the duty on the employer.
The law does not say how. Regular inspection and testing with written records is the accepted way to prove it has been done.
A short-term let licence in Scotland requires a PAT report on the movable appliances guests can use. HMO licensing with Dundee City Council also expects up-to-date appliance test records.
The certificate and results PDF are laid out so you can send them straight in with your paperwork.
Many insurance policies expect equipment to be tested regularly. After a fire or an injury, the first thing asked for is the test record.
Venues, festivals and hall owners around Dundee commonly ask performers, caterers and hirers for a current PAT certificate before they can plug in.
Two parts to every test
Every appliance goes through a formal visual inspection first, then the electrical tests. Most faults are found by eye, before the tester is even plugged in.
Part 1
Part 2
Each item gets a pass or fail label showing the result, the date and when it should be tested again.
Every appliance is given its own ID number and its results are recorded against it, so next time the history is already there.
Anything found along the way, such as a failed item, an overloaded adapter or a lead run under a carpet, is brought to the duty holder's attention before we leave.
Clear prices
The minimum visit is £74.99 and covers up to 30 items. Above that you pay per item, and the price per item drops as the count goes up. There is no VAT to add.
| Number of items | Price |
|---|---|
| 1 to 30 itemsThe minimum visit. Suits a rented flat, a small shop or a band. | £74.99 fixed price |
| 31 to 100 itemsSmall offices, cafes, salons, nurseries. | £1.59 per item |
| 101 to 200 itemsLarger offices, schools, care homes. | £1.49 per item |
| 201 to 500 itemsBig offices, workshops and whole buildings. | £1.39 per item |
| 501 items or more, or several sitesOne fixed price for the whole job, agreed before we start. | Quoted |
Worked examples: 50 items £79.50, 100 items £159, 200 items £298, 300 items £417, 500 items £695.
£95.40
£1.59 per item for 60 items. No VAT.
Book at this priceNot sure how many? Count the plugs. A desk usually has five or six: computer, monitor, lamp, charger and the extension lead.
Bulk PAT testing
Yes, and you do not have to ask for it. The discount is built into the price list.
Once you pass 100 items the price falls to £1.49 each, and past 200 items it falls to £1.39 each. The lower rate applies to every item, so 300 items come to £417 all in.
| ID | Item | Result |
|---|---|---|
| 0041 | Kettle | PASS |
| 0042 | Monitor | PASS |
| 0043 | 4-way extension lead | PASS |
| 0044 | Fan heater | FAIL |
| 0045 | Desk lamp | PASS |
Your report also shows the readings for each test, the date and the suggested re-test date.
Paperwork you can use
Everything is emailed, normally within one working day of the visit. Lost it? Ask and we will send it again.
Re-testing
For workplaces there is no fixed legal interval. It depends on the type of equipment, how often it is moved and how rough its surroundings are.
The intervals in the table are a sensible starting point, in line with HSE guidance. Your report suggests a date for each type of item, and we remind you when it is due.
Scottish landlords are the exception: appliances supplied in a let property must be tested at least every five years.
| Where it is used | Typical interval |
|---|---|
| Building sites and site tools | Every 3 months |
| Workshops, garages, commercial kitchens | Every 6 to 12 months |
| Bands, DJs and equipment that travels | Every 12 months |
| Shops, cafes, salons, schools | Every 12 months |
| Offices: kettles, heaters, extension leads | Every 1 to 2 years |
| Offices: computers and monitors that stay put | Every 2 to 4 years |
| Rented homes in Scotland | At least every 5 years |
Where we work
Dundee PAT Testing offers a quality PAT testing service throughout Dundee, Broughty Ferry and the towns and villages round about, on both sides of the Tay.
Further out in Angus, Perthshire or north Fife? Larger jobs are still worth a call. There is no call-out charge within the areas listed.
Questions
It depends who you are. Private landlords in Scotland must have the appliances they supply tested at least every five years under the Repairing Standard, and short-term let licences ask for a PAT report too. For employers and businesses the law does not use the words "PAT test". The Electricity at Work Regulations 1989 say electrical equipment must be kept safe, and regular inspection and testing with a written record is the accepted way to show you have done that.
The minimum visit is £74.99, which covers up to 30 items. Above that you pay per item, and the rate drops as the count goes up: £1.59 an item up to 100 items, £1.49 up to 200 and £1.39 up to 500. So 100 items come to £159 and 300 items come to £417. There is no VAT to add. Labels, plug repairs, the certificate and the results PDF are all included.
Yes. The discount is built into the price list. The rate is £1.59 an item up to 100 items, £1.49 from 101 to 200 and £1.39 from 201 to 500, and the lower rate applies to every item, not just the extra ones. For more than 500 items, or several buildings booked together, ask for a fixed price for the whole job. Already have a quote? Send it over and we will do our best to beat it.
There is no single legal interval for workplaces. It depends on the equipment and how hard a life it has. A drill on a building site needs checked far more often than a monitor that never leaves a desk. Landlords in Scotland have a fixed maximum of five years. We suggest an interval for each type of item on your report and remind you when the next test is due.
Each item is unplugged for a few minutes while it is tested, then plugged back in. Computers and tills need shut down first, so we work round your staff desk by desk, or come before opening, in the evening or at the weekend. Servers and anything that cannot be switched off get a visual inspection only, and that is noted on the report.
It gets a red fail label and you are told there and then what is wrong with it. The item is marked "do not use" and listed on the report, so you can have it repaired or replace it. Often the fix is cheap, such as a new plug or the right fuse.
Brand-new equipment from a known supplier should be safe to use, so it does not need a full test straight away. A quick visual check is still sensible, and we add new items to your register so they are picked up at the next visit.
Yes. Extension leads, multi-way adapters, detachable kettle-type leads, laptop power supplies and chargers are all tested and counted as items. Leads are often where the faults are found, because they get stood on, trapped and coiled up tight.
Yes. Venues, festivals and markets around Dundee often ask for a PAT certificate before you can plug in. Bring the kit to one place, or we come to your rehearsal room or lock-up, and you get a certificate you can email to the venue.
As a guide, a small office or flat with 20 to 40 items takes an hour or two. A few hundred items is usually a full day. Large sites are split over several visits to suit you.
Testing is carried out through Dundee Sparks by James Leslie, a qualified electrician with 40 years of experience.
Get a price
Tell us roughly how many items you have and where they are. You get a fixed price back, usually the same working day.
01382 721486Or email quotes@pattestingdundee.uk